Rabbit Interleukin 15 (IL-15) Quantitative Detection Kit (ELISA) Instructions for Use

Shanghai Hengdailao Trading Co., Ltd. is one of the authoritative suppliers of domestic biological reagents, specializing in the distribution of well-known brands in the field of biological sciences, with fast product delivery, quality, and brand guarantee.
This kit can only be used for scientific research, not for medical diagnosis.

Rabbit Interleukin 15 (IL-15) Quantitative Detection Kit (ELISA)
user's Guide
【Rabbit Interleukin 15 (IL-15) Elisa Kit Kit Name】
Rabbit Interleukin 15 (IL-15) Quantitative Detection Kit (ELISA)
[Rabbit Interleukin 15 (IL-15) Elisa Kit Kit Use]
Quantitative detection of interleukin 15 (IL-15) in rabbit serum, plasma and related liquid samples.
[Rabbit Interleukin 15 (IL-15) Elisa kit detection principle]
This kit uses double-antibody two-step sandwich enzyme-linked immunosorbent assay (ELISA). Add the standard and the test sample to the pre-coated rabbit interleukin 15 (IL-15) monoclonal antibody transparent enzyme label coated plate. After incubation for a sufficient time, wash to remove unbound components, and then add the enzyme label After incubating the working solution for a sufficient period of time, wash to remove unbound components. Substrates A and B are added in sequence, and the substrate (TMB) is converted into a blue product catalyzed by horseradish peroxidase (HRP), which turns yellow under the action of acid. The concentration of 15 (IL-15) was positively correlated. The OD value was measured at a wavelength of 450 nm. Based on the OD value of the standard and the sample, the content of rabbit interleukin 15 (IL-15) in the sample was calculated.
[Rabbit Interleukin 15 (IL-15) Elisa Kit Kit Composition]
1
Enzyme coated plate
12 holes × 8
7
Developer A liquid
6mL
2
Standard
0.3mL × 6 tubes
8
Developer B liquid
6mL
3
20 times concentrated washing liquid
25mL
9
Stop solution
6mL
4
Sample diluent
6mL
10
Instructions
1 serving
5
Special diluent
6mL
11
Sealing film
2 sheets
6
Enzyme reagent
6mL
12
sealed bag
1
Remarks: The concentration of standard products (No. 1 → No. 6) is: 4, 2, 1, 0.5, 0.25, 0.125ng / L.
[Rabbit Interleukin 15 (IL-15) Elisa kit required but not provided reagents and equipment]
1. 37 ℃ thermostat
2. Standard specification microplate reader
3. Precision pipettes and disposable tips
4. Distilled water
5. Disposable test tubes
6. Absorbent paper
[Rabbit interleukin 15 (IL-15) Elisa kit operating steps]
1. Preparation: Remove the reagent kit from the refrigerator and re-equilibrate at room temperature for 30 minutes.
2. Mixing solution: dilute the 20-fold concentrated washing solution with distilled water to the original one.
3. Add standard products and samples to be tested: take a sufficient number of enzyme-coated plates and fix them to the frame. Set up standard wells, sample wells to be tested and blank control wells, record the positions of each well in the standard wells. Add 50μL of standard product; first add 10μL of the sample to be tested, then add 40μL of sample diluent (that is, the sample is diluted 5 times); the blank control well is not added.
4. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.
5. Wash the plate: discard the liquid, pat dry on the absorbent paper, fill each well with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the washing plate 4 times (you can also use the washing machine to press Instructions for washing the board).
6. Add enzyme-labeled working solution: add 50μL of enzyme-labeled working solution to each well, without adding blank control wells.
7. Incubation: Incubate in a 37 ° C water bath or thermostat for 30 minutes.
8. Plate washing: Discard the liquid, pat dry on the absorbent paper, fill each hole with the washing liquid, let stand for 1min, shake off the washing liquid, pat dry on the absorbent paper, repeat the plate washing 4 times (you can also use the washing machine to press Instructions for washing the board).
9. Color development: add 50μL of developer A solution to each well, and then add 50μL of developer B solution. Mix with a plate mixer for 30s (or shake gently by hand for 30s), and avoid color development at 37 ℃ for 15min .
10. Termination: Remove the enzyme labeling plate and add 50μL of stop solution to each well to stop the reaction (the color changes from blue to yellow).
11. Determination: Zero the blank holes, and within 15 minutes after termination, measure the absorbance (OD value) of each well with a wavelength of 450 nm.
12. Calculation: According to the concentration of the standard product and the corresponding OD value, calculate the linear regression equation of the standard curve, and then calculate the corresponding sample concentration on the regression equation according to the OD value of the sample. You can also use various application software to Calculation. The final concentration is the actual measured concentration times the dilution factor.
[Rabbit Interleukin 15 (IL-15) Elisa kit sample requirements]
1. The sample cannot contain sodium azide (NaN3) because sodium azide (NaN3) is an inhibitor of horseradish peroxidase (HRP).
2. The specimen should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. The experiment should be carried out as soon as possible after extraction. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided.
3. The sample should be fully centrifuged, without hemolysis and particles.
[Rabbit Interleukin 15 (IL-15) Elisa kit notes]
1. The experiment is carried out in strict accordance with the instructions, and the result of the experiment must be determined by the reading of the microplate reader.
2. If the enzyme-labeled coated board is not used up after opening, it should be put into a sealed bag and added with desiccant immediately.
3. It is recommended that all standards, samples and blank controls be tested in duplicate, and the average value is taken to reduce the experimental error.
4. Keep in mind that the sample has been diluted 5 times. The calculation result is multiplied by 5 to obtain the actual concentration of the sample.
5. The quantitative range of this kit is 0.125-4ng / L, beyond this range, it is calculated from the extension of the standard curve. ), Multiplied by the total dilution factor is the final concentration of the sample.
6. If the color is too light, the substrate incubation time can be extended properly.
7. In order to avoid cross-contamination, the tips, samples and blank controls should be replaced with a new one for each addition; the common components such as enzyme working solution, sample diluent and substrate should be cantilevered, and they should not touch the microwells. ; Do not reuse the sealing film.
8. The kits are used within the warranty period, and different batches of reagents should not be mixed.
9. Substrate B is sensitive to light and avoid prolonged exposure to light.
[Rabbit interleukin 15 (IL-15) Elisa kit operating procedures summary]
Prepare reagents, samples and standards

Add prepared samples and standards, and react at 37 ℃ for 30 minutes
Wash the plate 4 times, add the enzyme reagent, and react at 37 ℃ for 30 minutes
Wash the plate 4 times, add color developing solutions A and B, and develop at 37 ℃ for 15 minutes
Add stop solution
Read OD value within 15 minutes
Calculation
[Rabbit Interleukin 15 (IL-15) Elisa kit detection range]
0.125ng / L – 4ng / L
[Rabbit Interleukin 15 (IL-15) Elisa Kit Specifications]
96 servings / box
【Storage of Rabbit Interleukin 15 (IL-15) Elisa Kit】
Store at 2-8 ℃, protected from light and moisture.
[Rabbit Interleukin 15 (IL-15) Elisa kit expiry date]
6 months

Stretch Film Information

What is Stretch Film?

Stretch film is a plastic film used to secure, bundle, and stabilize products. Stretch film, made from linear low-density polyethylene. When applying, the film is to be pulled and stretched around products to obtain tight and secured product loads. Stretch film comes in a variety of widths, thicknesses, and colors.

Types of Stretch Film


18
Bundling Stretch Film- Considered any film roll between 2-5 inches in width. Bundling film is a excellent alternative tape and plastic strapping for bundling multiple products together.
_MG_2566
Hand Stretch Film- Most of our hand film comes with a standard 3" core that will fit most any hand dispensers. Choose everything from clear to colored and even anti-static Stretch Wrap Film.
5
Extended Core Stretch Film- Offers built-in handles that are great for companies that need to wrap something on the go. The integrated handles are ideal for low volume output or mobile Stretch Wrap applications.
26
Machine Stretch Film- Our machine Pallet Stretch Wrap is offered in true standard gauged film as well as pre-stretched and equivalent film. All of our machine films can run on stretch wrap machines with up to a 250% stretch.
01
Colored Stretch Film- We offer transparent and opaque colored stretch film ideal for a variety of applications. Companies use transparent stretch film to color code loads to make for easy identification during shipping. The opaque film conceals loads and protects shipments from UV light.

Stretch Wrap

Pallet Wrap,Stretch Wrap,Plastic Wrap Roll,Wrapping Film,Stretch Wrap Film

Shenzhen Chengxing Packing & Material Co.,Ltd , https://www.cxpack.com